Is there any way to get the sensors to output in Kelvin?
----- Message from user-9d69468ed888@xymon.invalid -----
Hi, I'm wondering if anyone has been successful setting up and graphing an
item that fluctuates between positive and negative values? I'm trying to
trend the temperature of my freezer. When I created the rrd earlier today
(when positive values were generated) the graph was functional. When I put
my sensors inside the freezer (where the temperatures drop a few degrees
below zero F) the values wouldn't drop below zero on the graph.
I tried modifying the current rrd tool with:
rrdtool tune /home/hobbit/data/rrd/tice/freezer.rrd --minimum freezerf:U
(which did drop the minimum to nan) but I still couldn't get negatives to
show on the graph. I thought I'd delete the rrd and start over - but I
think now that the values are negative numbers the rrd won't even create.
Here is a snippet from my hobbitgraph and hobbitserver files
[freezer]
TITLE Freezer Temperature
YAXIS Degrees
DEF:tl=freezer.rrd:freezerf:AVERAGE
#CDEF:wipeoutf=tl,-1,*
DEF:cel=freezer.rrd:freezerc:AVERAGE
#CDEF:wipeoutc=cel,-1,*
LINE2:tl#@COLOR@:Temperature F
#LINE2:wipeoutf#@COLOR@:Temperature -F
LINE2:cel#@COLOR@:Temperature C
#LINE2:wipeoutc#@COLOR@:Temperature -C
COMMENT:\n
GPRINT:tl:LAST:Temperature F\: %2.1lf (cur)
GPRINT:tl:MAX:\: %2.1lf (max)
GPRINT:tl:MIN:\: %2.1lf (min)
GPRINT:tl:AVERAGE:\: %2.1lf (avg)\n
GPRINT:cel:LAST:Temperature C\: %2.1lf (cur)
GPRINT:cel:MAX:\: %2.1lf (max)
GPRINT:cel:MIN:\: %2.1lf (min)
GPRINT:cel:AVERAGE:\: %2.1lf (avg)\n
NCV_freezer="*:GAUGE"
(with freezer=ncv at the end of TEST2RRD and freezer and the end of GRAPHS).
Here is my script that generates the NCV for the rrd:
#!/bin/sh
COLUMN=freezer # Name of the column
COLOR=green # By default, everything is OK
[ -f ./.digitemprc ] || /usr/local/bin/digitemp_DS9097U -s/dev/ttyS0 -i
TEMPERATURE=$(/usr/local/bin/digitemp_DS9097U -s/dev/ttyS0 -a | awk '{print
$9}' | tail -1 | awk -F. '{print $1}')
if [ "${TEMPERATURE}" -gt 30 ]; then
COLOR=red
MSG="Temperature above 30 degrees"
else
COLOR=green
MSG="Temperature normal"
fi
# Section for data graphing
TEMPERATURE2_F=$(/usr/local/bin/digitemp_DS9097U -s/dev/ttyS0 -a | awk
'{print $9}' | tail -1)
TEMPERATURE2_C=$(/usr/local/bin/digitemp_DS9097U -s/dev/ttyS0 -a | awk
'{print $7}' | tail -1)
echo "freezerf : ${TEMPERATURE2_F}" > $BBTMP/freezer_f.txt
echo "freezerc : ${TEMPERATURE2_C}" > $BBTMP/freezer_c.txt
##
$BB $BBDISP "status $MACHINE.freezer $COLOR $MSG
`cat $BBTMP/freezer_f.txt`
`cat $BBTMP/freezer_c.txt`
"
rm $BBTMP/freezer_f.txt
rm $BBTMP/freezer_c.txt
exit 0
If anyone has an idea please let me know - I'd really like to trend this
data.
Thanks,
Matt
--
--Ben
Benjamin P. August
System Administrator - VPUE
Stanford University