Xymon Mailing List Archive search

raid bbwin monitoring

list Gonzalez Peto
Fri, 19 Jul 2013 15:20:30 +0200
Message-Id: <CABe7vS1nfsxK1-VdOrFR0EawfW3-cej6_i=user-b8eb19a418a9@xymon.invalid>

OK. This is the right url of 1.1.4
http://communities.quest.com/docs/DOC-9191

As I suspected the 2nd problem was actually a matter of capital vs small
letter. The correct response from the cmd script from windows regarding the
logical disks is "Ok" not "OK". So within this section
"REM Extract the status of each logical volume
REM -----------------------------------------"

I changed these to "Ok"
IF NOT "!_log_result!"=="Ok" SET _status=red
IF NOT "!_log_result!"=="Ok" SET _message="At least one logical volume is
in a failure state."
SET _ministatus=green
IF NOT "!_log_result!"=="Ok" SET _ministatus=red

So, now remains point 1 as it will not load the cmd script. It is supposed
to execute on a 5 min interval (for testing purposes).

I'll dig.

Please, if anyone can help, I would be grateful. Thank you


On Fri, Jul 19, 2013 at 2:58 PM, Gonzalez Peto <user-cf59771c3ad6@xymon.invalid> wrote:
I forgot to add:

On the server side, I have xymon 4.2.3 and I just added
"# raid" after the hostname entry I want to monitor in bb-hosts


On Fri, Jul 19, 2013 at 2:57 PM, Gonzalez Peto <user-cf59771c3ad6@xymon.invalid> wrote:
Hello

I read many posts about raid, hp raid and etc.
http://lists.xymon.com/archive/2010-February/027413.html

This pages says CheckHpRaid 1.1.4:
http://developer.sysco.ch/hobbit/
http://developer.sysco.ch/hobbit/CheckHpRaid.cmd
When I open it, it is 1.1.3

I found 1.1.4 @ http://xymonton.org/ and works well however I dont know
how to completely make it automatic

Few issues:
1. It seems that the cmd file will not be leaded automatically. If I
execute it manually, then all is ok, and the xymon server
receives this info. Then it will not receive more automatically.
I placed the cmd file in C:\Program Files\BBWin\ext\
I also tried by placing the cmd file in the root folder
I edited the the BBWIN.cfg file
<load value="cmd /c C:\CheckHpRaid_1.1.4.cmd" timer="5m"/>
or
<load value="cmd /c CheckHpRaid_1.1.4.cmd" timer="5m"/>

I took cmd /c from the bbwin manual chm file which comes with 0.12 version

2. Second problem is that the logical disk is reported ok and all
individual physical disk are ok, and yet I get color red for the logical
disk. :)
I am still trying to figure the source code where the if cases and
statuses are wrong?
And of course it says "At least one logical volume is in a failure
state."

Is anyone able to help?  Specially the first question - point 1. The
other one I think I will figure it out sooner or later.