Xymon Mailing List Archive search

Custom graph missing (continued)

list Ansiimire
Tue, 2 Oct 2007 16:57:28 +0300 (EAT)
Message-Id: <user-ca165774173e@xymon.invalid>

hullo..my question is not answered...i needed to know how to add a network
test on the available tests already..such as an stmp, cpu, memory etc

Hi Galen,
In fact the right graph setting is:

[sensors]
        TITLE Temperature
        YAXIS Deg Celsius
        DEF:cpu1tmp=sensors.rrd:CPU1Tmp:AVERAGE
        DEF:cpu2tmp=sensors.rrd:CPU2Tmp:AVERAGE
        DEF:brdtmp=sensors.rrd:BrdTmp:AVERAGE
        LINE2:cpu1tmp#FF0000:CPU-1 Tmp
        GPRINT:cpu1tmp:LAST: \: %5.1lf (cur)
        GPRINT:cpu1tmp:MAX: \: %5.1lf (max)
        GPRINT:cpu1tmp:MIN: \: %5.1lf (min)
        GPRINT:cpu1tmp:AVERAGE: \: %5.1lf (avg)\n
        LINE2:cpu2tmp#00FF00:CPU-2 Tmp
        GPRINT:cpu2tmp:LAST: \: %5.1lf (cur)
        GPRINT:cpu2tmp:MAX: \: %5.1lf (max)
        GPRINT:cpu2tmp:MIN: \: %5.1lf (min)
        GPRINT:cpu2tmp:AVERAGE: \: %5.1lf (avg)\n
        LINE2:brdtmp#0000FF:Brd Tmp
        GPRINT:brdtmp:LAST:   \: %5.1lf (cur)
        GPRINT:brdtmp:MAX: \: %5.1lf (max)
        GPRINT:brdtmp:MIN: \: %5.1lf (min)
        GPRINT:brdtmp:AVERAGE: \: %5.1lf (avg)\n

It work fine, thanks, I will modify my sensors.conf to set the CPU as
CPU-1 Tmp even the machine is mono-proc and send "CPU-2 Tmp : 0"

But now I want in the same [sensors] tag graph the fans in second one to
get on sensors page the temperatures graph and the fan graph, how to do
that ?

Sam.


Galen Johnson a écrit :
I think your best bet is going to be to somehow split out the rrds to
separate files (sensors.brdtmp.rrd, sensors.cpu1tmp, etc).  I haven't
had the opportunity to have to attempt this but I'd be very surprised if
others haven't.

Once you get it into separate rrds, and you have a consistent definition
in each one, such as temperature, you should be able to try it using the
way it was previously defined.

All that said, one thing I am curious about is why the line definition
is "LINE2:p at RRDIDX@#@COLOR@:@RRDPARAM@" instead of
"LINE at RRDIDX@:p at RRDIDX@#@COLOR@:@RRDPARAM@"?...this question isn't
directed at you, Sam.

=G=

-----Original Message-----
From: Sam Przyswa [mailto:user-c968d3ed43a2@xymon.invalid]
Sent: Monday, October 01, 2007 4:25 PM
To: user-ae9b8668bcde@xymon.invalid
Subject: Re: [hobbit] Custom graph missing (continued)

Galen Johnson a écrit :
I've had success with NCV without needing to add the test name to
GRAPHS (ncv seems to be sufficient).  What I usually do in the graph
config would be to explicitly define my definitions, something like:

[sensors]
        TITLE Temperature
        YAXIS Celsius
        DEF:cpu1tmp=sensors.rrd:CPU1Tmp:AVERAGE
        DEF:cpu2tmp=sensors.rrd:CPU2Tmp:AVERAGE
        DEF:brdtmp=sensors.rrd:BrdTmp:AVERAGE
        LINE1:cpu1tmp#FF0000:CPU-1 Tmp
        LINE2:cpu2tmp#00FF00:CPU-1 Tmp
        LINE3:brdtmp#0000FF:CPU-1 Tmp
        GPRINT:cpu1tmp:LAST: \: %5.1lf (cur)
        GPRINT:cpu1tmp:MAX: \: %5.1lf (max)
        GPRINT:cpu1tmp:MIN: \: %5.1lf (min)
        GPRINT:cpu1tmp:AVERAGE: \: %5.1lf (avg)\n
        GPRINT:cpu2tmp:LAST: \: %5.1lf (cur)
        GPRINT:cpu2tmp:MAX: \: %5.1lf (max)
        GPRINT:cpu2tmp:MIN: \: %5.1lf (min)
        GPRINT:cpu2tmp:AVERAGE: \: %5.1lf (avg)\n
        GPRINT:brdtmp:LAST: \: %5.1lf (cur)
        GPRINT:brdtmp:MAX: \: %5.1lf (max)
        GPRINT:brdtmp:MIN: \: %5.1lf (min)
        GPRINT:brdtmp:AVERAGE: \: %5.1lf (avg)\n

It looks like you're pulling from a single rrd (sensors.rrd) instead of
multiple rrds (sensors.*.rrd, such as sensors.cpu1tmp.rrd) (which is
what the function def looks for).  I'm sure there's a better way but I
know adding it manually works.  Of course, if your rrd changes, your
graph won't catch it.

Yes it's my problem because I have some mono-proc machines where the
label is "CPU Tmp" or I have machines with "CPU Fan" and "Brd Fan" how
can I do ?

Sam.

-----Original Message-----
From: Sam Przyswa [mailto:user-c968d3ed43a2@xymon.invalid]
Sent: Monday, October 01, 2007 1:36 PM
To: Hobbit Users List
Subject: [hobbit] Custom graph missing (continued)

Hi Hobbit users,

I create à custom monitor script to check lm-sensors temperatures from
Linux boxes named "sensors" the data are sent by the remote client as:

CPU-1 Tmp : 21.88
Brd Tmp : 19.12
CPU-2 Tmp : 22.38 > 17 reached! (Warnlevel Yellow)

To respect the name-colon-value formatted report

This is well displayed on the machine's monitor page and the alerts are
sent by mail as well, but the graph is not create in monitor and trends
page. I put on server in hobbitserver.cfg

TEST2RRD="cpu=la,...,sensors=ncv

GRAPHS="...,ncv,...,sensors

NCV_sensors="*:GAUGE"

The sensors.rrd dump give:

<!-- Round Robin Database Dump --><rrd> <version> 0003 </version>
        <step> 300 </step> <!-- Seconds -->
        <lastupdate> 1191248506 </lastupdate> <!-- 2007-10-01 16:21:46
CEST -->

        <ds>
                <name> CPU1Tmp </name>
                <type> GAUGE </type>
                <minimal_heartbeat> 600 </minimal_heartbeat>
                <min> 0.0000000000e+00 </min>
                <max> NaN </max>

                <!-- PDP Status -->
                <last_ds> UNKN </last_ds>
                <value> 2.2662800000e+03 </value>
                <unknown_sec> 0 </unknown_sec>
        </ds>

        <ds>
                <name> BrdTmp </name>
                <type> GAUGE </type>
                <minimal_heartbeat> 600 </minimal_heartbeat>
                <min> 0.0000000000e+00 </min>
                <max> NaN </max>

                <!-- PDP Status -->
                <last_ds> UNKN </last_ds>
                <value> 2.0797200000e+03 </value>
                <unknown_sec> 0 </unknown_sec>
        </ds>

        <ds>
                <name> CPU2Tmp </name>
                <type> GAUGE </type>
                <minimal_heartbeat> 600 </minimal_heartbeat>
                <min> 0.0000000000e+00 </min>
                <max> NaN </max>

                <!-- PDP Status -->
                <last_ds> UNKN </last_ds>
                <value> 2.3722800000e+03 </value>
                <unknown_sec> 0 </unknown_sec>
        </ds>
[...]

And in the hobbitgraph.cfg I have:

[sensors]
        FNPATTERN sensors.(.+).rrd
        TITLE Temperature
        YAXIS Celsius
        DEF:p at RRDIDX@=@RRDFN@:temperature:AVERAGE
        LINE2:p at RRDIDX@#@COLOR@:@RRDPARAM@
        GPRINT:p at RRDIDX@:LAST: \: %5.1lf (cur)
        GPRINT:p at RRDIDX@:MAX: \: %5.1lf (max)
        GPRINT:p at RRDIDX@:MIN: \: %5.1lf (min)
        GPRINT:p at RRDIDX@:AVERAGE: \: %5.1lf (avg)\n

I forget to say this is the 4.2.0 version installed on Ubuntu and some
client machine on Debian.

What I have missed ?

Thanks for your help.

Sam.

--

Sam Przyswa - Chef de projet
Arial Concept - Intégrateur Internet
36, rue de Turin - 75008 - Paris - France
Tel: XX XX XX XX XX - Fax: XX XX XX XX XX
Skype ID: arial-concept
Web: http://www.arial-concept.com - Email: user-76cdd9de94f1@xymon.invalid


--
Ce message a été vérifié par MailScanner
pour des virus ou des polluriels et rien de
suspect n'a été trouvé.