New UPS monitor added to Xymonton
I find this works quite well for me. Notice the smaller line size the farther down it goes - this enables you to actually see the bigger lines above (behind) the others. Also note that the LINE is not being commented at the end but is a identifying a hex color. http://imgur.com/33K2w.png [in-voltage] TITLE Input AC Voltage YAXIS VAC DEF:FIRSTUPS=in-voltage.rrd:FIRSTUPS:AVERAGE DEF:SECONDUPS=in-voltage.rrd:FIRSTUPS:AVERAGE DEF:THIRDUPS=in-voltage.rrd:FIRSTUPS:AVERAGE LINE6.5:FIRSTUPS#00CCCC:FIRSTUPS LINE3.5:SECONDUPS#CC0000:SECONDUPS LINE1.5:THIRDUPS#FFFF00:THIRDUPS COMMENT:\n GPRINT:FIRSTUPS:LAST: FIRSTUPS \: %5.1lf%s (cur) GPRINT:FIRSTUPS:MAX: \: %5.1lf%s (max) GPRINT:FIRSTUPS:MIN: \: %5.1lf%s (min) GPRINT:FIRSTUPS:AVERAGE: \: %5.1lf%s (avg)\n GPRINT:SECONDUPS:LAST: SECONDUPS \: %5.1lf%s (cur) GPRINT:SECONDUPS:MAX: \: %5.1lf%s (max) GPRINT:SECONDUPS:MIN: \: %5.1lf%s (min) GPRINT:SECONDUPS:AVERAGE: \: %5.1lf%s (avg)\n GPRINT:THIRDUPS:LAST: THIRDUPS \: %5.1lf%s (cur) GPRINT:THIRDUPS:MAX: \: %5.1lf%s (max) GPRINT:THIRDUPS:MIN: \: %5.1lf%s (min) GPRINT:THIRDUPS:AVERAGE: \: %5.1lf%s (avg)\n Josh Luthman Office: XXX-XXX-XXXX Direct: XXX-XXX-XXXX XXXX Wayne St Suite XXXX Troy, OH XXXXX On Wed, Jul 28, 2010 at 7:39 PM, Josh Luthman <user-4c45a83f15cb@xymon.invalid> wrote:
I see! Would be nice to have an example or place to document this in more detail. Could we start a public Xymon Wiki for these kinds of things? I believe I have it correct - three DEF, LINE and GPRINT lines (note that they are being escaped with \ ) for three UPS units. I'm not certain as the data is all at 120v at the moment. Josh Luthman Office: XXX-XXX-XXXX Direct: XXX-XXX-XXXX XXXX Wayne St Suite XXXX Troy, OH XXXXX On Wed, Jul 28, 2010 at 6:20 PM, Ralph Mitchell <user-00a5e44c48c0@xymon.invalid> wrote:You mean like this extract from hobbitgraph.cfg?? [users] TITLE Users and Processes YAXIS # DEF:p=procs.rrd:la:AVERAGE DEF:u=users.rrd:la:AVERAGE AREA:p#00CC00:Processes LINE1:u#000099:Users Multiple DEFs with as many rrds as you like... :) Ralph Mitchell On Wed, Jul 28, 2010 at 2:59 PM, Josh Luthman <user-4c45a83f15cb@xymon.invalid> wrote:Never mind, missing the name of my UPS on hobbitgraphs. How does one put multiple UPS on a single graph, though? I'm looking at the disk statement and I don't see where a second rrd file comes in to play. Is it necessary for one graph to load from one rrd file? Josh Luthman Office: XXX-XXX-XXXX Direct: XXX-XXX-XXXX XXXX Wayne St Suite XXXX Troy, OH XXXXX On Wed, Jul 28, 2010 at 2:41 PM, Josh Luthman <user-4c45a83f15cb@xymon.invalid> wrote:I am having an issue with the graphs. Is it possible the RRD was created without supporting of two decimal places? They are being referenced on their pages but the image does not show up. The RRD files exist and do have values: -> rrdtool dump out-voltage.rrd |grep "name\|type\|last_ds" <name> 111111111</name> <type> GAUGE </type> <last_ds> 119.00 </last_ds> <name> 222222222</name> <type> GAUGE </type> <last_ds> 121.00 </last_ds> <name> 33333333333</name> <type> GAUGE </type> <last_ds> 120.00 </last_ds> Josh Luthman Office: XXX-XXX-XXXX Direct: XXX-XXX-XXXX XXXX Wayne St Suite XXXX Troy, OH XXXXX On Wed, Jul 28, 2010 at 12:59 PM, Josh Luthman <user-4c45a83f15cb@xymon.invalid> wrote:That fixed it! Thank you! Josh Luthman Office: XXX-XXX-XXXX Direct: XXX-XXX-XXXX XXXX Wayne St Suite XXXX Troy, OH XXXXX On Wed, Jul 28, 2010 at 12:46 PM, Bill Arlofski <user-0b8af203a56e@xymon.invalid> wrote:On 07/28/10 12:29, Josh Luthman wrote:>Unless I am mistaken, the test I wrote will be set the status to yellow if theUPS load is greater than or equal to $yellowtest (80%) and the status will be set to red if the UPS load is eualto or greater than $redtest (80%).While this may be your intention that is not what I'm seeing. I am getting a red condition with these loads. - UPS load % for apcxxxxxr01 apcyyyy01 apczzzzzzzzz01 on 127.0.0.1 apcxxxxxx01 : 51.00 apcyyyy01 : 11.00 apczzzzzzzz01 : 12.00 My yellow and red are 80 and 90 like you suggest (or at least your default is =) -> cat ~myhobbituser/server/ext/xymon_nut_ups-load.sh|grep test datatest="ups\.load:" yellowtest="80" redtest="90" Josh LuthmanAh... I see it... Your UPS reports load % with two decimal points (51.00), mine reports % load with one (35.6) So the logic in the script is correct, but the part where I was stripping past the decimal failed to take into account more than one decimal. By only stripping the decimal and one numeral past it, the test is saying "if 510 > 90 then set the status to red" To fix it, change the line: datanopoint=`echo "$data" | "$SED" -e 's/\.[0-9]//'` to datanopoint=`echo "$data" | "$SED" -e 's/\.[0-9]\{1,2\}//'` P.S. I already made all the changes I mentioned in may last email and will be putting up the simplified versions possibly later today, including this fix. Thanks Josh -- Bill Arlofski Reverse Polarity, LLC