On 11-01-2012 21:16, Mark Hinkle wrote:
I think there's a counter that isn't reset.
Just guessing, but I would say you are close. Seems more like there is a
counter missing. As mentioned in the old discussion included in a
previous email, there is a single alert duration clock when there really
needs to be both yellow and red clocks. Alert state issue again, maybe?
[snip]
If the powers-that-be are willing to open the question of "alert state",
then please, please also look into the long standing recovery message
issue. Specifically, if you are emailing on yellow and paging on red, a
test that goes green->yellow->red->yellow->green will result in a red
page but only an email recovery. See
http://lists.xymon.com/archive/2008-July/020107.html and
http://lists.xymon.com/archive/2008-July/020152.html. Apologies if this
seems like a thread hijack, that is not the intent at all, but rather
these issues seem very closely related with respect to maintaining alert
state and to what degree.
You're probably quite correct that there is some state information in
the alert module that does not keep track of "enough" state to handle
both of these feature requests. So it would make sense to look at them
at the same time.
Regards,
Henrik