Mike,

No, the lom variables are set and when run manually it produces what I am
seeing.  Exit status is 0 when I run it but I assume it's using awk/egrep
etc.. etc.. to get values?

LOM_COMMAND="/usr/sbin/lom"
LOM_OPT="-pfvt"

We do have SONWlom packages.

system      SUNWlomm       LOMlite manual pages
system      SUNWlomr       LOMlite driver (root)
system      SUNWlomu       LOMlite Utilities (usr)

Output from manual run.

# /usr/sbin/lom -pfvt
PSUs:
1 OK
Fans:
1 OK speed 84%
Supply voltages:
 1               5V status=ok
 2              3V3 status=ok
 3             +12V status=ok
 4             -12V status=ok
 5         VDD core status=ok
System status flags (circuit breakers):
 1             USB0 status=ok
 2             USB1 status=ok
 3              SCC status=ok
System Temperature Sensors:
 1        Enclosure 32 degC : warning 67 degC : shutdown 72 degC
System Over-temperature Sensors:
 1             ÿCPU status=ok


Painful, as these are the only servers let to solve?

Regards
Sean.


On Sat, Sep 12, 2009 at 8:22 PM, Mike Arnold <user-95d566fbb20b@xymon.invalid> wrote:
My wild guess would be that you also need to run "/usr/sbin/lom -pfvt" on
the v120 to get the temperature and voltage output?  Do you have SUNWlom*
installed on the v120?

--
-m

... so long as the people do not care to exercise their freedom, those
who wish to tyrranize will do so; for tyrants are active and ardent,
and will devote themselves in the name of any number of gods, religious
and otherwise, to put shackles upon sleeping men.
               -- Voltarine de Cleyre

Shaun Phillips wrote:
Ralph,

Yes the bbcmd command was very useful.  Ran that with the new bb-prtdiag
script from : http://xymonton.trantor.org/doku.php/monitors

Now there is a compatability with the bb-prtdiag.sh script and v120
servers.

if you run the script on one as follows.

# /usr/platform/sun4u/sbin/prtdiag -v
System Configuration:  Sun Microsystems  sun4u Sun Fire V120
(UltraSPARC-IIe
648MHz)
System clock frequency: 100 MHz
Memory size: 1024 Megabytes
========================= CPUs =========================
                    Run   Ecache   CPU    CPU
Brd  CPU   Module   MHz     MB    Impl.   Mask
---  ---  -------  -----  ------  ------  ----
 0     0     0      648     0.5   13       3.3

========================= IO Cards =========================
     Bus#  Freq
Brd  Type  MHz   Slot  Name                              Model
---  ----  ----  ----  --------------------------------
 0   PCI-1  33    12   ebus
 0   PCI-1  33     3   pmu-pci10b9,7101
 0   PCI-1  33     3   lomp
 0   PCI-1  33     7   isa
 0   PCI-1  33    12   network-pci108e,1101              SUNW,pci-eri
 0   PCI-1  33    12   usb-pci108e,1103.1
 0   PCI-1  33    13   ide-pci10b9,5229
 0   PCI-1  33     5   network-pci108e,1101              SUNW,pci-eri
 0   PCI-1  33     5   usb-pci108e,1103.1
 0   PCI-2  33     8   scsi-glm                          Symbios,53C896
 0   PCI-2  33     8   scsi-glm                          Symbios,53C896

No failures found in System
===========================
========================= HW Revisions =========================
ASIC Revisions:
Cheerio: ebus Rev 1
System PROM revisions:
  CORE 1.0.12 2002/01/08 13:00
dtcp-sbr001a:root#

You get the above output.  Which is not showing enough I would think.
 The
hobbit page shows the output as follows.


 Fri Sep 11 13:34:40 GMT 2009 [image: red]prtdiag reports voltage
problems
!!!

prtdiag reports voltage problems !!!
 1               5V status=ok
 2              3V3 status=ok
 3             +12V status=ok
 4             -12V status=ok
 5         CPU core status=ok
 6            +3VSB status=ok  PSUs:
1 OK
Fans:
1 OK speed 98%
2 OK speed 100%
3 OK speed 100%
4 OK speed 100%
Supply voltages:
 1               5V status=ok
 2              3V3 status=ok
 3             +12V status=ok
 4             -12V status=ok
 5         CPU core status=ok
 6            +3VSB status=ok
System status flags (circuit breakers):
 1        SCSI-Term status=ok
 2             USB0 status=ok
 3             USB1 status=ok
 4              SCC status=ok
System Temperature Sensors:
 1        Enclosure 29 degC : warning 67 degC : shutdown 72 degC
System Over-temperature Sensors:
 1             ÿCPU status=ok


As you can see that's not the normal out that one would expect?  Any
ideas?
Currently so far the new bb-prtdiag.sh has cleard up the majority of
errors
I was facing with some servers.


Regards
Shaun


On Wed, Sep 9, 2009 at 8:01 PM, Ralph Mitchell
<user-00a5e44c48c0@xymon.invalid>wrote:
Try using bbcmd to execute bb-prtdiag.sh
   server/bin/bbcmd   /path/to/bb-prtdiag.sh

bbcmd sets up the environment properly for the script.  You need more
than
just BBHOME.

Ralph Mitchell


On Wed, Sep 9, 2009 at 1:52 PM, Shaun Phillips <
user-176e7038266c@xymon.invalid> wrote:
ok,

So I edited the script and add -vvv to the interpreter line.

And now see egrep and bb errors.


  if [ -s "$REDLINE" ]; then
    COLOR="red"
  fi
  # NOW USE THE BB COMMAND TO SEND THE DATA ACROSS
  $BB $BBDISP "status $MACHINE.$TEST $COLOR `$DATE` `$CAT $REDLINE`
`$CAT
$YELLOWLINE` `$CAT $BBTMP/$MACHINE.$TEST` "
fi
*egrep: syntax error
./bb-prtdiag.sh: /bin/bb: not found*
if [ "$DEBUG" != "Y" ]; then
  clean_up_our_mess
fi

I have logged in, su'd to hobbit on the clinet, set my BBHOME variable
and
then proceed to ( ./bb-prtdiag.sh ) run the script.

Any thoughts?


On Tue, Sep 1, 2009 at 3:14 AM, Everett, Vernon <
user-9da1a1882f49@xymon.invalid> wrote:
You are right.
I was thinking of sunhw.sh on deadcat.
Apologies for muddying the water.
Should have my coffee *before* I post to the list. :-)

Cheers
   V


-----Original Message-----
From: Craig Cook [mailto:user-850f03189cf7@xymon.invalid]
Sent: Monday, 31 August 2009 9:14 PM
To: user-ae9b8668bcde@xymon.invalid
 Subject: RE: [hobbit] bb-prtdiag.sh - Sun SPARC Enterprise M9000
Server
I am having truble with the bb-prtdiag script on "Sun SPARC
Enterprise
M9000 Server " and also "SUNW,UltraAX-i2"  hardware.  Always saying
something is wrong when I cant see anything wrong?

The M9000 has not explicitly been added for support.

Check the readme with the bb-prtdiag tar file for how to run the built
in
debug.
There is also information in the comment section at the top of the
script.

Support for UltraAX-i2 has been added, run debug to find out why/where
it
is complaining.
bb-prtdiag is a very simple test. It looks at the return code of the
prtdiag command.
No.  bb-prtdiag does not look at the return code from running prtdiag.
 If you want a simple prtdiag check there is another one on deadcat.

Craig


NOTICE: This email and any attachments are confidential.
They may contain legally privileged information or
copyright material. You must not read, copy, use or
disclose them without authorisation. If you are not an
intended recipient, please contact us at once by return